Acoustic underlay for timber: a complete floor specification

At a glance

Who it is for
Owners and installers laying engineered, solid, parquetry or bamboo floors in apartments
What it covers
Floating, glue-down and plywood systems, published test figures, build-up height, moisture, warranty
Rating schemes involved
ΔLw and Ln,w (laboratory), L'nT,w and AAAC stars (on site)
Last verified
25 September 2026, against the ATFA information sheet and the test reports linked below

Timber’s character is visible in the grain. The way it feels and sounds underfoot also depends on how the floor is supported and fixed.

Floating engineered boards, bonded timber and solid boards on a supporting system need different details. Settle the installation method first. Then check the complete construction for acoustic evidence, moisture provisions and the height available at doors.

Which timber floor system are you laying?

The Australasian Timber Flooring Association (ATFA) information sheet on acoustic underlays describes three systems for apartments. Foam underlay is “used with floating engineered, laminate and bamboo floors”. Adhesive-fixed underlay suits floating floors and “adhesive-fixed engineered and parquetry floors”. And “For solid strip timber flooring, plywood is usually adhesive-fixed to the underlay and the timber flooring fixed to the plywood.”

Timber floor systems over acoustic underlay compared (laboratory results on bare concrete slabs, no ceiling)
SystemHow it is fixedUsual underlayPublished exampleWatch for
Floating engineered or bambooBoards lock to each other, not to the underlayFoam (often IXPE) or rubber, laid loose14 mm engineered on 2 mm IXPE: ΔLw 18 dB, Ln,w 61 dB (CSIRO, 150 mm slab)Timber maker's underlay rules; expansion gaps
Direct-stick engineered or parquetryUnderlay glued to the slab, boards glued to the underlayRubber, rubber and cork, or cork14 mm engineered bonded on 5 mm REGUPOL sonus eco 5: ΔLw 16 dB, Ln,w 62 dB (CSIRO, 150 mm slab)Warranty: often outside published practice
Solid boards on plywood or particleboardSheet glued to the underlay, boards fixed to the sheetRubber mat in the published example19 mm T&G on 18 mm yellow tongue on 17 mm REGUPOL sonus curve 17: ΔLw 27 dB, Ln,w 53 dB (CSIRO, 170 mm slab)Height; fixings must not pierce the underlay
Floor build-up and impact pathAn impact meets the floor covering and underlay. Energy can travel through the supporting structure and radiate sound into the room below. This is a schematic, not a tested construction.Impact on the floorFloor coveringUnderlayConcrete slabEnergy travels through the structureSound radiates into the room below
Floor build-up shown schematically. The whole construction matters.

How much do rubber and cork underlays reduce impact noise?

Here are the published laboratory figures we could trace to a data sheet or test report for underlays under timber. All are ΔLw (improvement, higher is better) and, where given, Ln,w (the tested floor’s level, lower is better).

Published laboratory results for acoustic underlays under timber
Underlay and materialTimber on topFixingTest slabLn,wΔLw
REGUPOL sonus eco 5, 5 mm tyre rubber and cork14 mm engineeredFloating150 mm, CSIRO 201759 dB17 dB
REGUPOL sonus eco 514 mm engineeredGlued both sides150 mm, CSIRO 201762 dB16 dB
REGUPOL sonus eco 519 mm block parquetryGlued both sides150 mm56 dB20 dB
REGUPOL sonus curve 17, 17 mm dimpled tyre rubber19 mm T&G on 18 mm yellow tongueGlued170 mm, CSIRO 200453 dB27 dB
Amorim AcoustiCORK T66, 3 mm cork and rubberGlued-down woodGlued140 mm62 dB16 dB
DAMTEC black uni, 2 mm PU foam granules and cork10 mm two-layer parquetryGluedNot statedNot stated19 dB
2 mm IXPE foam with film14 mm engineeredFloating150 mm, CSIRO 202461 dB18 dB

Sources: REGUPOL tests RG110 and RG114, the sonus eco 5 data sheet, test RG018, the Amorim T66 data sheet, the DAMTEC brochure and CSIRO report INR289-16-1. DAMTEC says its brochure figures are its “maximum tested values”.

Three things stand out. Most results sit between 16 and 20 dB. The big number, 27 dB, came from a much deeper build-up with a particleboard layer. And the bare slabs in these labs measured around Ln,w 80 dB, far worse than a real apartment with a ceiling, so these are comparisons between products, not predictions for your unit.

Is glue-down or floating timber quieter?

In the one matched pair we found, floating was slightly quieter. REGUPOL had CSIRO test the same 14 mm engineered board on the same 5 mm sonus eco 5 underlay both ways. Floating gave Ln,w 59 dB (ΔLw 17 dB). Glued to the underlay and the underlay glued to the slab gave Ln,w 62 dB (ΔLw 16 dB). That is one product and one board, so treat it as a hint, not a rule.

Glue-down is the ATFA’s system for parquetry and direct-stick engineered boards. The catch is warranty. The ATFA says “When fixing directly to the acoustic underlay material, flooring manufacturer warranties and performance warranties need to be considered as this often falls outside of published floor installation practices.”

What about solid floorboards on battens or plywood?

Solid strip boards need a nailing base. In the ATFA’s apartment system, plywood is glued to the acoustic underlay and the boards are fixed to the plywood, so no nail reaches the slab. That matters: the ABCB handbook warns that a resilient rubber underlay must not be “bridged” by nails and screws running into the slab, because they “diminish its performance”.

If an installer proposes battens instead of a sheet, ask for a test report for that exact batten, pad and board system, and check how the battens are held down without fixings through the underlay.

Will the new floor be too high at doors and stairs?

It can be. The REGUPOL sonus curve 17 test build stacked 19 mm boards on 18 mm yellow tongue on a 17 mm rubber mat. That is about 54 mm before adhesive, enough to catch doors, clash with a tiled bathroom and make a step at every threshold. REGUPOL markets its thinner 6 mm sonus curve 6 as “suitable for constructions with limited floor heights”, and publishes ΔLw 23 dB for it under T&G timber on yellow tongue (product page).

The ABCB handbook asks designers to keep “sufficient ceiling height” and to avoid “an excessively high step” between carpet and hard floors. Before you choose an underlay, measure the height available at each door, the kitchen and bathroom thresholds, and the top and bottom of the stairs. Stairs are a separate detail; ask the timber maker how treads and nosings are fixed, and whether the underlay continues onto them.

Moisture: what does timber need on a slab?

Timber takes up moisture. The ATFA explains that if moisture vapour beneath a floor “is too high … then it will cause the flooring to absorb the moisture”, which can lead to cupping. It also warns that “Moisture vapour barriers are not ‘water proofing membranes’ and they will allow a small amount of moisture vapour transmission through them.”

So the slab has to be dry enough for the flooring system first. Ask the timber maker for its moisture limit and required barrier, and ask the underlay maker whether its product can sit on, or be glued over, that barrier.

Installation basics for timber on acoustic underlay

  • Keep every edge off the walls. The ATFA explains that a floor hard up against walls lets noise travel through the walls into the next unit. For fixed floors it describes skirting set 2 to 5 mm above the floor with flexible sealant; for floating floors, “Do not use a sealant at skirtings” and keep a gap.
  • Check flatness. The ATFA gives no more than 3 mm under a 1.5 m straight edge for adhesive and mechanically fixed floors, and 3 mm under a 1.0 m straight edge for floating floors other than laminate.
  • Use the adhesives the underlay maker names. REGUPOL’s bonded test used its own one-part polyurethane adhesive.
  • Get the whole system in writing. The ATFA says “both the flooring manufacturer and the acoustic underlay supplier need to be fully accepting of the installation method used”.

What to check on the data sheet

  • Is the test result for timber, and for your fixing method: floating, glued, or on plywood?
  • Laboratory ΔLw and Ln,w with the standard (ISO 10140-3 and ISO 717-2, or older ISO 140-8) and the lab named
  • Full build-up: board type and thickness, any sheet layer, slab thickness, ceiling
  • Total height of the finished floor
  • Density or weight per square metre, and any compression and recovery figures
  • Which adhesives and moisture barrier the maker approves
  • Written acceptance of the system from the timber maker and the underlay supplier

For the wider picture across every floor type, read the acoustic underlay hub. For how timber compares with other floors in an apartment, see our guide to acoustic flooring.

Questions, answered

What is the best acoustic underlay for engineered timber?

There is no single best one, because the result depends on your slab, your ceiling and how the boards are fixed. Compare underlays on the same board and fixing method, using laboratory ΔLw and Ln,w from a named lab, and check that the timber maker accepts the underlay. For an apartment, ask for an on-site result from a similar building too.

Can you glue engineered timber to an acoustic underlay?

Some systems do exactly that, with the underlay glued to the slab and the boards glued to the underlay. The ATFA warns that fixing directly to an acoustic underlay often falls outside published installation practice, so get written acceptance from both the timber maker and the underlay supplier before you start.

Does bamboo flooring need acoustic underlay?

If it is going into an apartment, check your by-law first. The ATFA lists foam underlay under floating bamboo as a common system. In one on-site test, 14 mm bamboo on a 2 mm IXPE foam measured L'nT,w 43 in a Sydney apartment with a 200 mm slab and a plasterboard ceiling. Your building may differ.

How thick should acoustic underlay be for timber floors?

As thick as the system and the tested build-up need, and no thicker than your doors, thresholds and the timber maker allow. The published tests we read show thickness alone does not decide the result: a 2 mm foam and a 5 mm rubber and cork mat scored within 1 dB of each other under floating engineered boards.

Do I need a moisture barrier under a timber floor on a concrete slab?

Ask the timber maker, because timber absorbs moisture vapour from the slab and can cup. The ATFA notes that vapour barriers are not waterproofing membranes and let some vapour through, so the slab also has to be dry enough for the flooring system.

Is the underlay decision different for floating and glued timber?

Yes. A floating system needs support compatible with the board joints, while a bonded system also depends on the approved adhesives and substrate preparation. Compare reports and instructions for the installation method you will actually use.

Sources

  1. Installation over acoustic underlays (consumer information) · Australasian Timber Flooring Association · Accessed 2026-09-25
  2. REGUPOL sonus eco 5 technical data (Version 2022.v1) · REGUPOL Australia · Accessed 2026-09-25
  3. Acoustic test RG110, REGUPOL sonus eco 5 under 14 mm engineered timber, non-bonded · REGUPOL Australia (CSIRO test) · Accessed 2026-09-25
  4. Acoustic test RG114, REGUPOL sonus eco 5 under 14 mm engineered timber, bonded · REGUPOL Australia (CSIRO test) · Accessed 2026-09-25
  5. Acoustic test RG018, REGUPOL sonus curve 17 under T&G timber on yellow tongue · REGUPOL Australia (CSIRO test) · Accessed 2026-09-25
  6. REGUPOL sonus curve 6 product page · REGUPOL Australia · Accessed 2026-09-25
  7. AcoustiCORK T66 Material Data Sheet · Amorim Cork Composites · Accessed 2026-09-25
  8. DAMTEC acoustic insulation directly under floor coverings (brochure, 2021) · KRAIBURG Relastec · Accessed 2026-09-25
  9. CSIRO Acoustic Measurement Report INR289-16-1, engineered timber on 2 mm IXPE underlay (7 February 2024) · CSIRO · Accessed 2026-09-25
  10. Certificate of Performance, Impact sound insulation of 2 mm EverQuiet IXPE underlay (11 May 2022) · Koikas Acoustics · Accessed 2026-09-25
  11. Sound Transmission and Insulation in Buildings Handbook (NCC 2022) · Australian Building Codes Board · Accessed 2026-09-25
  12. AAAC Guideline for Apartment and Townhouse Acoustic Rating, Explanatory Note V2.0 (May 2023) · Association of Australasian Acoustical Consultants · Accessed 2026-09-25

Goes well with