On this page
- Why is tile the loudest floor on a concrete slab?
- How does an acoustic mat under tiles work?
- What acoustic underlay is used under tiles in Australia?
- Does a thicker mat make tiles quieter?
- Can you use acoustic underlay under tiles in a bathroom?
- Crack isolation and tile limits
- How much height does acoustic underlay add under tiles?
- What to check on the data sheet
A tiled floor can make an apartment feel composed and continuous. Beneath that finish, the acoustic mat, adhesive and substrate need to work as one specified system.
The detail becomes particularly important at bathrooms, thresholds and doors. Acoustic performance cannot be considered separately from waterproofing, support or finished height.
Why is tile the loudest floor on a concrete slab?
A tile bonded to a slab adds a hard layer and no cushion. When a heel or a dropped pan hits it, the energy goes straight into the concrete and comes out as sound in the apartment below.
The on-site numbers show how large the gap is. In 18 Kingsford Street [2016] QBCCMCmr 78, an owner replaced carpet with porcelain tiles laid without acoustic underlay. An acoustic engineer measured LnT,w 75 to 80 in the unit below. The adjudicator ordered the owner to fix it with carpet and underlay, or with “new tiles laid over an appropriate acoustic membrane”.
In Body Corporate for Admiralty Towers II v Johnson [2017] QCATA 29, the tribunal recorded carpeted areas in an apartment tower at about LnT,w 28 and tiled kitchens at about 61 to 65. It also noted that a 10 dB difference is typically heard as halving or doubling the sound. Lower LnT,w is quieter, and these are field results, measured in real buildings.
How does an acoustic mat under tiles work?
The mat is a resilient layer that separates the tile, or a screed, from the slab. It absorbs part of each impact before it reaches the concrete. It only works if nothing hard bridges around it, so makers ask for gaps at the walls. ARDEX TB147 asks for a gap of at least 6 mm at walls and protrusions “to allow total isolation of the tiles from the adjacent building structure”, and the gap is filled with silicone.
There are two ways to build it:
- Mat under the tile adhesive (direct stick). The mat is glued to the slab and the tile is adhered to the mat. This keeps the floor low.
- Mat under a screed. The mat goes on the slab, a sand and cement screed goes on the mat, and the tile goes on the screed. This is higher and heavier, and it tested better in the reports below.
What acoustic underlay is used under tiles in Australia?
These are the products we found with an Australian data sheet that shows a tile test. ΔLw is the laboratory improvement over the bare slab, so higher is better. Ln,w is the laboratory result for the whole floor, so lower is better.
| Product | Mat type and thickness | Build-up tested | Published result | Lab or field |
|---|---|---|---|---|
| DAMTEC Standard | Rubber and cork, 2 mm | 9 mm ceramic adhered, 140 mm slab, no ceiling | ΔLw 18 dB, Ln,w 56 | Lab |
| DAMTEC Standard | Rubber and cork, 3 mm | Same | ΔLw 17 dB, Ln,w 56 | Lab |
| REGUPOL sonus multi 4.5 (formerly 4515) | PU foam and cork, 4.5 mm | 10 mm porcelain bonded, 150 mm slab | ΔLw 17 dB, Ln,w 61 | Lab |
| ARDEX DS 40 | Mineral-filled PU mat, 4.5 mm | Not stated on the datasheet | 14 dB (DIN EN ISO 140-8) | Lab |
| REGUPOL sonus multi 4.5 | PU foam and cork, 4.5 mm | 8 mm ceramic on 30 mm bonded screed, 150 mm slab | ΔLw 19 dB, Ln,w 60 | Lab |
| REGUPOL sonus core 5 | Recycled tyre rubber, 5 mm | 8 mm ceramic on 30 mm screed, 150 mm slab | ΔLw 21 dB, Ln,w 58 | Lab |
| REGUPOL sonus core 10-S | Recycled tyre rubber, 10 mm | Same | ΔLw 23 dB, Ln,w 53 | Lab |
| DAMTEC Multi | Recycled rubber, 4 mm | 60 mm cement screed, 140 mm slab, no ceiling | ΔLw 24 dB, Ln,w 54 | Lab |
| ImpactaMat 800 | Recycled rubber, 5 mm | Ceramic tile bonded to mat, 150 mm slab, no ceiling | 20 dB better than the bare slab (LnT,w + CI 56) | Field |
Sources: Damtec Standard tiling brochure, Damtec under-screed brochure, REGUPOL sonus multi 4.5, sonus core 5 and sonus core 10-S technical data, the ARDEX DS 40 datasheet and Embelton’s ImpactaMat tile brochure. REGUPOL also lists sonus curve 6, a 6 mm profiled mat for screeds, at ΔLw 24 dB under tile and screed.
Read the table with care. Damtec tested on a 140 mm slab and REGUPOL on a 150 mm slab, in different laboratories. A 1 dB gap between two reports does not make one product better. ARDEX also quotes a “field result 18 dB” with its X 56 adhesive, but the datasheet does not say which building it came from. If you want to compare the two biggest names directly, see Regupol vs Damtec.
The National Construction Code (NCC 2025, F7D5) sets a laboratory Ln,w of 62 or lower for a floor between apartments in a new Class 2 or 3 building. Your by-law may ask for a field LnT,w number instead, which includes your ceiling and your building. Our guide to acoustic ratings explained shows how the two differ.
Does a thicker mat make tiles quieter?
Not under bonded tile, going by the published tests. In Damtec’s series under 9 mm ceramic, 2 mm gave ΔLw 18 dB and 3 mm and 4 mm gave 17 dB. Under a screed, thickness helped in REGUPOL’s series: 21 dB for the 5 mm mat and 23 dB for the 10 mm mat.
Thicker mats can also move more under a tile. MAPEI’s work method statement C06 recommends a screed over the mat “especially for acoustic matting thicknesses above 4.5 mm which are usually more compressible”. Damtec asks for a trial installation before its Multi mat at 4 mm or more goes under direct-stick tile (Damtec Multi tiling brochure).
Can you use acoustic underlay under tiles in a bathroom?
Often, but the waterproofing has to be designed with the mat, not around it. MAPEI’s C06 statement cites AS 3740-2021, the standard for waterproofing domestic wet areas, and asks for a screed with falls to it. Each maker then shows where the membrane goes:
- ARDEX DS 40. TB147 gives two options. In one, the screed to falls goes down first, the mat on top, then the membrane over the mat. In the other, the mat goes on the slab, the screed over it, then the membrane on the screed. The datasheet says it suits domestic bathrooms, but not permanently wet areas or public bathrooms and toilets.
- Vibramat. The Acoustic Supplies wet area detail puts the membrane on the screed, above the mat, to stop efflorescence from the sand and cement. It asks for a bond breaker at the floor to wall junction and notes that acoustic engineers normally require a 10 mm gap between screed and wall.
- DAMTEC standard. KRAIBURG’s data sheet says it suits tiles in wet areas “provided an appropriate waterproofing system is used”.
- ImpactaMat. Embelton says the mat is porous and recommends a moisture barrier in wet areas.
Crack isolation and tile limits
Some mats also act as a crack isolation layer. The ARDEX DS 40 datasheet says it bridges cracks up to 1 mm and carries loads up to 2 kN/m². It also sets tile limits: at least 15 x 15 cm, stoneware at least 8 mm thick and natural stone at least 15 mm thick, with movement joints carried up through the tiles.
Damtec’s tiling page says its Multi mat, at about 970 kg/m³, gives a more rigid base that reduces the risk of grout cracking. That is the maker’s claim, not a test result.
How much height does acoustic underlay add under tiles?
With a direct-stick mat, you add the mat and its adhesive. ARDEX DS 40 is 4.5 mm, and TB147 asks for a tile adhesive bed of at least 3 mm over it. Damtec Standard is 2 or 3 mm.
A screed system adds much more. REGUPOL’s tests used a 30 mm screed. Damtec’s under-screed system is for screeds “greater than 35mm thick at waste” and was tested with 60 mm. Check door clearances, thresholds and your shower falls before you choose.
What to check on the data sheet
- A tile test, not only a timber or vinyl test, with the tile thickness stated
- Slab thickness and whether a ceiling was present
- Lab (ΔLw, Ln,w) or field (LnT,w) result, and the report number
- The approved tile adhesive and trowel notch
- The maker's wet area detail, if the room has a floor waste
- Perimeter isolation: the gap size and the sealant
- Minimum tile size and thickness
The AAAC’s explanatory note warns that no underlay on its own can be guaranteed to reach a rating in your building. If the by-law number is tight, ask an acoustic consultant about a sample test on site. Our strata flooring rules guide explains the approval steps.
Join the waitlist below to hear when
Questions, answered
Can you put acoustic underlay under tiles?
Yes. Tile needs a firm mat that is bonded to the slab, with the tile adhesive spread on top, or a mat under a screed with the tile laid on the screed. The thin foam underlays sold for floating timber and laminate floors are not made for tiles. Use a mat whose maker publishes a tile test and approves the adhesive you plan to use.
What thickness of acoustic underlay do tiles need?
Mats bonded under tile are usually 2 to 5 mm. In Damtec's laboratory series under 9 mm ceramic tile, 2 mm gave ΔLw 18 dB and 3 and 4 mm gave 17 dB, so thicker was not better. MAPEI recommends a screed over mats thicker than 4.5 mm because they are usually more compressible.
Can I use an acoustic mat under bathroom tiles?
Often yes, but only with the mat maker's wet area detail and a membrane that meets AS 3740. ARDEX says DS 40 suits domestic bathrooms but not permanently wet areas or public bathrooms, and Embelton says ImpactaMat is porous and needs a moisture barrier in wet areas.
Will an acoustic mat stop my tiles cracking?
Some mats claim to help. ARDEX says DS 40 bridges cracks up to 1 mm. Damtec says its dense Multi mat reduces deflection and the risk of grout cracking, and asks for a trial installation before 4 mm or thicker Multi goes under direct-stick tile. No mat makes up for a weak substrate or missing movement joints.
How much does acoustic underlay for tiles cost?
Most makers do not publish prices, so get three quotes that name the mat, its thickness and the adhesive. Embelton is an exception and lists ImpactaMat sheet prices on its website; see our rubber acoustic underlay guide for the figures and date.
Sources
- 18 Kingsford Street [2016] QBCCMCmr 78 · Queensland Commissioner for Body Corporate and Community Management (via AustLII) · Accessed 2026-09-25
- Body Corporate for Admiralty Towers II v Johnson [2017] QCATA 29 · Queensland Civil and Administrative Tribunal · Accessed 2026-09-25
- NCC 2025 Volume One, Part F7 Sound transmission and insulation · Australian Building Codes Board · Accessed 2026-09-25
- AAAC Guideline for Apartment and Townhouse Acoustic Rating - Explanatory Note V2.0 · Association of Australasian Acoustical Consultants · Accessed 2026-09-25
- Direct-stick tiled flooring with DAMTEC Standard (brochure) · Damtec Australasia · Accessed 2026-09-25
- Direct Stick Tiling Applications · Damtec Australasia · Accessed 2026-09-25
- Direct-stick tiled flooring with DAMTEC Multi (brochure) · Damtec Australasia · Accessed 2026-09-25
- Under screed flooring with DAMTEC Multi (brochure) · Damtec Australasia · Accessed 2026-09-25
- DAMTEC standard Product Data Sheet 9401-R-09 · KRAIBURG Relastec · Accessed 2026-09-25
- REGUPOL sonus multi 4.5 Technical Data · REGUPOL Australia · Accessed 2026-09-25
- REGUPOL sonus core 5 Technical Data · REGUPOL Australia · Accessed 2026-09-25
- REGUPOL sonus core 10-S Technical Data · REGUPOL Australia · Accessed 2026-09-25
- REGUPOL sonus curve 6 · REGUPOL Australia · Accessed 2026-09-25
- ARDEX DS 40 Datasheet · ARDEX Australia · Accessed 2026-09-25
- Technical Bulletin TB147: installation of ARDEX DS40 in internal applications · ARDEX Australia · Accessed 2026-09-25
- Work Method Statement C06: installation of tiles over acoustic matting · MAPEI Australia · Accessed 2026-09-25
- ImpactaMat Flooring Acoustic Rubber Underlay, Part 2: Tiles and Vinyl · Embelton · Accessed 2026-09-25
- Vibramat detail: ceramic and stone floors in wet areas · Acoustic Supplies · Accessed 2026-09-25